Heat exchangers will not produce steam until they reach 500°C. The steam | Heat exchangers will not produce steam until they reach 500°C. The steam produced is exactly 500°C hot, even if the exchanger is hotter. Heat exchangers have a heat capacity of 1 MJ/C. Thus, they can buffer 500 MJ of heat energy across their working range of 500C to 1000C, and require 485 MJ of energy to warm up from 15C to 500C when initially placed. | ||
== Calculating steam production Rate == | == Calculating steam production Rate == |
Revision as of 13:25, 10 May 2018
Heat exchanger |
Recipe |
|
+ + + → | |
Total raw |
|
+ + + |
Recipe |
|
+ + + → | |
Total raw |
|
+ + + |
Map color |
|
Fluid storage volume |
Input: 200 |
Health |
200 |
Resistances |
Explosion: 0/30% |
Stack size |
50 |
Dimensions |
2×3 |
Energy consumption |
10 MW |
Maximum temperature |
1000 °C |
Mining time |
0.1 |
Prototype type |
|
Internal name |
heat-exchanger |
Required technologies |
|
Produced by |
|
The heat exchanger exchanges heat between a heat source and a fluid. It is usually used together with a nuclear reactor and steam turbines.
Heat exchangers produce 103 steam/second which is 500°C degrees hot.
Heat exchangers will not produce steam until they reach 500°C. The steam produced is exactly 500°C hot, even if the exchanger is hotter. Heat exchangers have a heat capacity of 1 MJ/C. Thus, they can buffer 500 MJ of heat energy across their working range of 500C to 1000C, and require 485 MJ of energy to warm up from 15C to 500C when initially placed.
Calculating steam production Rate
Heat exchangers produce 103 steam/second. This is not shown in the game toolboxes, but can be calculated by using the energy consumption: 1 Heat exchanger consumes 10MW, so it's putting 10,000,000 joule of energy into heating water/steam per second. To heat up 1 unit of water 1 degree, 200 joules are needed, so the heat exchanger is heating up 50,000°C in total. But the water only gets heated up from 15°C to 500°C, so by 485°C. So the 50,000°C are enough to heat up 103 units of steam per second, since 50,000 / 485 = 103.09
.
Another way to calculate this is by relying on Steam turbine data; A steam turbine consumes 60 steam/second and produces 5.8MW (assuming 500°C steam). This means a single unit of 500°C steam has 5.8MW / 60/s = 0.9666 MJ
of energy. A steam engine produces 10 MJ a second, therefore it produces 10MJ / 0.0966MJ = 103.448275862
steam a second.
History
- 0.15.0:
- Introduced