Line 1: | Line 1: | ||
== Basics == | == Basics == | ||
An electric pole - part of the [[electric | An electric pole - part of the [[electric system]]. Based on [[Prototype/EntityWithHealth]]. | ||
== Properties == | == Properties == | ||
This prototype inherits all the properties from [[Prototype/EntityWithHealth]]. | This prototype inherits all the properties from [[Prototype/EntityWithHealth]]. | ||
=== pictures === | |||
'''Type''': [[Types/RotatedSprite]] | |||
=== radius_visualisation_picture === | |||
'''Type''': [[Types/Sprite]] | |||
=== maximum_wire_distance === | === maximum_wire_distance === | ||
Type: [[Types/ | '''Type''': [[Types/double]] | ||
The maximum distance between this pole and any other connected pole - if two poles are farther apart than this, they cannot be connected together directly. Corresponds to "wire reach" in the item tooltip. | The maximum distance between this pole and any other connected pole - if two poles are farther apart than this, they cannot be connected together directly. Corresponds to "wire reach" in the item tooltip. | ||
Max value is 64. | |||
=== supply_area_distance === | === supply_area_distance === | ||
Type: [[Types/ | '''Type''': [[Types/float]] | ||
The "radius" of this pole's supply area. Corresponds to ''half'' of the "supply area" in the item tooltip. | The "radius" of this pole's supply area. Corresponds to ''half'' of the "supply area" in the item tooltip. If this is 3.5, the pole will have a 7X7 supply area. | ||
Max value is 64. | |||
=== | === track_coverage_during_build_by_moving === | ||
Type: | '''Type''': [[Types/bool]] | ||
=== connection_points === | === connection_points === | ||
Type: | '''Type''': [[Types/table]] of [[Types/WireConnectionPoint]] | ||
Revision as of 10:44, 20 January 2018
Basics
An electric pole - part of the electric system. Based on Prototype/EntityWithHealth.
Properties
This prototype inherits all the properties from Prototype/EntityWithHealth.
pictures
Type: Types/RotatedSprite
radius_visualisation_picture
Type: Types/Sprite
maximum_wire_distance
Type: Types/double
The maximum distance between this pole and any other connected pole - if two poles are farther apart than this, they cannot be connected together directly. Corresponds to "wire reach" in the item tooltip.
Max value is 64.
supply_area_distance
Type: Types/float
The "radius" of this pole's supply area. Corresponds to half of the "supply area" in the item tooltip. If this is 3.5, the pole will have a 7X7 supply area.
Max value is 64.
track_coverage_during_build_by_moving
Type: Types/bool
connection_points
Type: Types/table of Types/WireConnectionPoint