Types/FluidBox: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
(0.16)
(Added image)
Line 1: Line 1:
== Basics ==
== Basics ==
[[File:Fluidboxes.png|thumb|550px|Visual representation of base_area, base_level and height. When all the fluidboxes are connected, the water leaves fluidbox A and flows into the other 3 boxes through fluidbox B until the water level is equal in all boxes. For more info about fluids, see [[Fluid system#See also]].]]
Used to set the fluid amount an entity can hold, as well as the connection points for pipes leading into and out of the entity.
Used to set the fluid amount an entity can hold, as well as the connection points for pipes leading into and out of the entity.


Line 15: Line 16:


'''Default''': 1
'''Default''': 1
A base area of 1 will hold 100 units of water, 2 will hold 200, etc...


Must be greater than 0.
Must be greater than 0.

Revision as of 12:34, 8 August 2019

Basics

Visual representation of base_area, base_level and height. When all the fluidboxes are connected, the water leaves fluidbox A and flows into the other 3 boxes through fluidbox B until the water level is equal in all boxes. For more info about fluids, see Fluid system#See also.

Used to set the fluid amount an entity can hold, as well as the connection points for pipes leading into and out of the entity.

Mandatory properties

pipe_connections

Type: Types/table of Types/PipeConnectionDefinition

Max number of members is 255.

Optional properties

base_area

Type: Types/double

Default: 1

Must be greater than 0.

base_level

Type: Types/double

Default: 0

height

Type: Types/double

Default: 1

Must be greater than 0.

filter

Type: Types/string

Can be used to specify which fluid is allowed to enter this fluid box. [1]

render_layer

Type: Types/RenderLayer

Default: "object"

pipe_covers

Type: Types/Sprite4Way

The pictures to show when another fluid box connects to this one.

pipe_picture

Type: Types/Sprite4Way

minimum_temperature

Type: Types/double

The minimum temperature allowed into the fluidbox.

minimum_temperature = 100.0

maximum_temperature

Type: Types/double

The maximum temperature allowed into the fluidbox.

maximum_temperature = 1000.0

production_type

Type: Types/string

Default: "None"

Possible values:

  • "None"
  • "input"
  • "input-output"
  • "output"

secondary_draw_order

Type: Types/int8

Default: 1

Set the secondary draw order for all orientations.

secondary_draw_orders

Type: Types/table of Types/int8

Default: {north = 1, east = 1, south = 1, west = 1}

Set the secondary draw order for each orientation.

Example

fluid_box =
    {
      base_area = 1,
      height = 2,
      base_level = -1,
      pipe_covers = pipecoverspictures(),
      pipe_connections =
      {
        {type = "input-output", position = {-2, 0.5}},
        {type = "input-output", position = {2, 0.5}}
      },
      production_type = "input-output"
    },