In other languages: 中文

Smart inserter: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
Line 49: Line 49:


== Not working by default ==
== Not working by default ==
This needs to be connected to the [[Circuit network]] or have a filter or condition set, otherwise it won't work!
This device works only if
 
* it has a filter set '''and/or'''
When connected to the circuit network, it begins to work immediately, because the "no condition" is set. Set one or more conditions, and the inserter will follow the instructions.
* it is connected to a [[Circuit network]] and/or [[Logistic network]].


When connected to a network, it begins to work immediately, because the "no condition" is a valid condition.


Set one or more conditions, and the inserter will follow the instructions by combining it with logical 'AND'.


== See also ==
== See also ==

Revision as of 13:24, 24 October 2014

Template:Machinery

More advanced electric inserter. In most cases, the smart inserter will be used to stop production of an item after a certain condition is met (e.g. enough items), when configured as output on an assembly.

Usage

Works at the same speed as a fast inserter. It needs to be configured to work. Configuration is done by opening the inserter interface (right mouse).

Wiring

When used for Circuit network this needs to be wired:

Easy wired logistic set up.gif

You can use the copy/paste (Shift-RMB for copy and Shift-LMB for paste) to copy the conditions and the connected wire.

The pole needs to be in wiring-reach and and you need to have wires in your inventory.

Configuration

34hvpew.png

The smart inserter interface has two parts: the "filter" and the "condition".

Filter part

File:Mpstark-UlSB2pr.gif

If used (you are not forced to use the filter, it works also by using the condition part only!), the smart inserter moves only items which are in this filter (up to five items can be filtered).

It takes then only "filtered" items from a belt or other stacks (chests, assemblies, etc.). For example, if a belt contains iron and copper plates, and filter is set to iron plate, the inserter will take only iron plates, and don't touches copper plates.

Condition part

Example condition: "Work only if the count of Alien science pack is lower than 50."

This switches the smart inserter on/off. It will work only if all set conditions are true, please refer to the Circuit network to see, how this can be used! Condition could be based on red/green circuit (the first two lines, but you need to connect red/green wire to the inserter first!) or logistic network (the last line, but you need a Roboport and the inserter must be inside of the logistic area). Typical use is to limit input/output of assembly machine: if the circuit and/or logistic network contains < X items of this type then load the assembly machine. As soon as X items are in logistic network, assembly machine is not loaded any more. Usually it's easier to limit output, so items are not removed from assembly machine and when internal storage of the assembler is full it will stop producing.

There are some examples in the forum, which will show you some of the common and not so common usages.

Using both

Finally you can use both, filter and condition, so it will only move items of one type if there are less/more than X items of that type in the logistic network (or wires).

Not working by default

This device works only if

When connected to a network, it begins to work immediately, because the "no condition" is a valid condition.

Set one or more conditions, and the inserter will follow the instructions by combining it with logical 'AND'.

See also

Template:MachineNav