In other languages: Česky Deutsch Français 日本語 Polska Русский 中文

Fluid system: Difference between revisions

From Official Factorio Wiki
Jump to navigation Jump to search
(Changed links going to the redirect File:Offshore-pump.png to go to File:Offshore pump.png.)
(Readded throughput formula based on findings in https://forums.factorio.com/103145)
 
(44 intermediate revisions by 15 users not shown)
Line 1: Line 1:
{{Languages}}
{{Languages}}
'''Fluids''' are non-solid items, such as water and oil.
'''Fluids''' are non-solid items, such as [[water]] and [[oil]]. They can normally only exist inside entities for fluid handling (like [[pipe]]s), and buildings that have fluids as input ingredients or products (like an [[oil refinery]]).
 
== Fluids ==
[[File:fluids_gui.png|thumb|300px|right|"Fluids" tab on the [[production statistics]] screen.]]
The following fluids are available in-game:
 
: {{Imagelink|Water}} {{Imagelink|Crude oil}} {{Imagelink|Petroleum gas}} {{Imagelink|Light oil}} {{Imagelink|Heavy oil}} {{Imagelink|Lubricant}} {{Imagelink|Sulfuric acid}} {{Imagelink|Steam}}


== Mechanics ==
== Mechanics ==
Fluids cannot be carried by the player, moved using [[inserters]], dropped on the ground, nor stored in chests, unless the fluids are stored in [[barrel]]s. They cannot be spilled or even dumped in a lake, and are counted in continuous fractions, rather than discrete integers.<br>
When the player picks up a structure that contains fluids, the contained fluid will try to flow into connected structures and any excess fluid that does not fit is destroyed.


Fluids can only exist inside [[pipe]]s and certain buildings, meaning they cannot be carried by the player, moved using [[inserters]], dropped on the ground, or even dumped in a lake. They are counted in continuous fractions, rather than discrete integers. Liquids can be silently destroyed by removing buildings or pipes. Only one type of fluid can occupy a [[pipe]] at a time. Two fluids will never mix.
=== Storage ===


Fluids can be transported by [[Fluid system#Piping|piping]], [[barrel]]s, or [[fluid wagon]]s.
In the game, fluid is held in entities that behave as vessels (fluid boxes) of a defined size (volume). The vessels automatically connect to each other if their inputs/outputs are adjacent (pipes connect to all directions) and allow fluids to flow between them.


=== Pressure ===
The '''volume''' of fluid contained in a fluid box is a value between 0 and the maximum volume. For instance, the pipe can hold 100 units of fluid, therefore the value in the pipe can be a number between 0 and 100. The '''level''' of fluid in a given entity is manifested by a percentage of the entity's maximum volume that is being occupied by a fluid. It can be observed in pipes and tanks; they have windows through which the fluid is seen at a certain level, or perhaps even as just a small trickle.


Here "pressure" = current_fluid_level / max_amount.
=== Fluid mixing ===
[[File:Pipe_GUI.png|right|frame|GUI of a pipe inside a fluid system containing mixed fluids. Clicking the trash can icon next to a fluid will flush that fluid from the system.]]
The game will prevent players from accidentally mixing fluids when placing most buildings, e.g. [[pipe]]s containing different fluids cannot be placed directly next to each other. However, not every possible case of fluid mixing is considered, so the player may still mix fluids accidentally or by purposely working around the building restrictions. A fluid system containing mixed fluids can be cleared of the undesired fluids in the GUI of a pipe or [[storage tank]] that is part of that fluid system. Fluids that are flushed from pipes or storage tanks are deleted permanently.


The pressure of a fluid in a pipe can be seen through the pipe window. A pipe with high pressure will show itself nearly full, a pipe with low pressure will show a small trickle of the fluid.
In a fluid system that contains mixed fluids, the alt-mode fluids icons on its pipes/storage tanks will reflect the fluid that is contained in that specific structure. So, it may look like a fluid system only contains one fluid when looking at the alt-mode icons, when in reality it contains multiple fluids which are located in some other connected structures. The GUI of a connected pipe or storage tank will always show all fluids contained in the fluid system.<br>
This means that if the game disallows connecting two pipes that look like they contain the same fluid with "Cannot connect systems with different fluids", one of the fluid systems contains multiple fluids. This can solved easily by opening the GUIs of the pipes that the game refuses to connect which will show the extra fluid and allow flushing it from the fluid system.


When two neighboring containers (pipes or fluid storage) store the same fluid at different pressure, some of the content of the fuller container will move into the less filled one. The speed of this transfer depends on the difference in pressure.
=== Flow ===


Fluids do not flow out of a building's input tile or into its output tile. [[Pump]]s partially override pressure, putting all their content into their output tile.
All connected tanks and pipes are treated as a single vessel in that ''the level of fluid must be equal in all parts'', to even out pressure exacted by a higher fluid level on smaller ones. This is why level is also often referred to as ''pressure'', even though pressure is actually caused by a difference in level between two entities. All flow of fluid that happens between pipes is to achieve this balance (pumps practically ignore it and buildings disrupt it; more on that further below). The flow rate between pipes is dependent on pressure (the difference in level between the adjacent entities), it becomes slower as pipes even their levels out.


=== Volume ===
Coming back to how the 'level' is defined, this also means that all connected pipes and tanks attempt to even out to the same percentage of their respective volumes. For example, if 12,550 units of fluid are left to flow into a storage tank of 25,000-unit capacity with one pipe of 100-unit capacity connected, there will be 12,500 units in the storage tank and 50 units in the pipe, both being filled to the same '''percentage''' (50%) of their capacities, even though the amounts themselves are unequal.


In the game, fluid is held in fluid boxes with a defined size (equivalent to volume). Connected fluidboxes allow fluids to flow between them. For instance, each pipe is a 1x1 fluid box with a connection in each direction.
Machines that produce fluids put them in their output slots, which are related to a specifically labeled output pipe socket somewhere on the machine (pressing Alt reveals the labels). The slot will attempt to empty itself into the entity connected to the machine's socket, unless it is full, or contains a non-matching fluid. Machines that consume fluids also have an accordingly labeled pipe input socket. If an entity containing the correct fluid is connected to it, the machine will start behaving like a pipe that can never be filled, meaning the fluid from connected pipes and tanks drains into the machine at a fixed rate, until the machine's input slot is full. There may be machines that have pipe sockets for both input and output (like a [[electric mining drill|drill]] placed over [[uranium ore]]). They then drain the fluid for themselves first, and once full, behave as a regular pipe that attempts to even out its level with adjacent entitites. If there are multiple output/input sockets for one fluid on a machine, their activity is distributed to them equally unless some of them are blocked/full.


The volume of fluid contained in a fluid box is value between 0 and the fluidbox size, so for instance the pipe can hold 100 Units of fluid, so the value in the fluid box can be any number between 0 and 100.
=== Temperature ===
Temperature is currently only relevant in heating water as a medium for power generation. Even though all fluids in the game have a temperature value, it is generally the default 15°C.


=== Temperature ===
Energy, whether harnessed from [[fuel]] in [[boiler]]s, or from [[Nuclear power (research)|nuclear power]] through [[heat exchanger]]s, can be used to turn [[water]] to [[steam]], being a [[Energy and work|liquid form of work]]. Steam holds energy at a ratio of 0.2 kJ per °C per unit. In other words: 0.2 kJ of work is necessary to heat a unit of steam by one °C. Since steam/water is set to have a maximum temperature of 1000°C and minimum of 15°C, the most work that can be done on one unit is 197 kJ.
 
In practice, this is barely utilized in a great variety: Boilers only output steam of 165°C temperature, and heat exchangers only output 500°C hot steam, never hotter, never colder; if insufficient energy is supplied, the heaters do not output steam altogether. The steam also does not grow colder over time. Using the 165°C steam in a [[steam engine]] has the same effect as using it in a [[steam turbine]], although it is impractical, since turbines are made to consume 500°C (superheated) steam, generating proportionally more power. All of this makes for no need of exact calculations.
 
== Transport ==
Fluids can be transported through pipelines, barrels, or railway. It is generally practical to use piping for short-distance distribution to machines (or barrelling, if there is need to use belts), and railway transportation for longer distances.
 
=== Pipelines ===
[[File:pipes_carrying_fluids.png|thumb|312px|Eight pipelines, each carrying a different fluid.]]


Work contained in [[fuel]] is converted by the [[boiler]]s or [[heat exchanger]]s to [[steam]], which is just a [[Energy and Work|liquid form of work]]. This steam holds energy at ratio of
'''[[Pipe|Pipes]]''' are the most basic way to channel fluids from A to B. They automatically connect to any adjacent pipe and can do so to all four cardinal directions simultaneously. [[Pipe to ground|Underground pipes]] only work in two opposite directions, linking to another underground pipe on one side, and to another entity on the other. If a pipe section becomes too long without using pumps, all fluid inside it will be "spread thin", resulting in very slow flow and preventing machines to use its contents effectively. '''[[Storage tank|Tanks]]''' behave the same as pipes, except their volume is much greater, which can cause this inconvenience over a much smaller distance if multiple tanks are used. Underground pipes can help alleviate this issue; although they can connect a distance of up to 10 tiles, their volume is always equivalent to two pipes.
0.2 kJ per °C per Unit
In other words: 0.2 kJ of work is necessary to heat water by one °C.


Since steam/water is set to have a maximum temperature of 500°C and minimum of 15°C, the most work that can be in an unit of water is 97 kJ.  
'''[[Pump]]s''' use electrical power to transfer fluids in one direction very quickly. They also block any back-flow, which means they can pressurize a section of piping, filling it as much as possible. This is very useful to counteract the "thin spread" outlined above, among other things. They can also be disabled using the [[circuit network]] which stops fluid flow through the pump.


== Types ==
The table below shows how fast will fluid flow in a pipeline with a certain frequency of pumps. If a higher flow rate is desired, pumps should be placed more frequently. Because underground pipes only count as 2 regular pipes in terms of volume, a full-length section only counts as two pipes in this table, if a pump is placed between each underground section. Placing a filled storage tank before a pump ensures maximum possible flow rate and is therefore a suitable start of any pipeline.


{| class="wikitable"
{| class="wikitable mw-collapsible"
| {{imagelink|water|Water}} || Can be extracted from water using the [[offshore pump]].
|-
! Number of pipes<br>between two pumps !! Maximum flow&nbsp;<br>(u/sec)
|-
| 0 (pump to pump) || 12000
|-
| 0 (tank to pump) || 12000
|-
|-
| {{imagelink|steam|Steam}} || Water heated in a [[boiler]] or [[heat exchanger]]. Mainly used to produce power.
| 0 (pump to tank) || 12000
|-
|-
| {{Imagelink|Crude oil|Crude oil}} || Extracted from oil fields by [[Pumpjack]]s and can be converted to [[Petroleum gas]], [[Light oil]], and [[Heavy oil]].
| 0 (pump to boiler to pump) || 12000
|-
|-
| {{Imagelink|Petroleum gas|Petroleum gas}} || Converted from [[Crude oil]]. Used to create various items.
| 0 (pump to 2 boilers to pump) || 6000
|-
|-
| {{Imagelink|Light oil|Light oil}} || Converted from [[Crude oil]]. Used to create various items. Can be converted into [[Petroleum gas]].
| 1 || 6000
|-
|-
| {{Imagelink|Heavy oil|Heavy oil}} || Converted from [[Crude oil]]. Can be converted to [[Light oil]] and [[Lubricant]].
| 2 || 3000
|-
|-
| {{Imagelink|Sulfuric acid|Sulfuric acid}} || Converted from [[Sulfur]], [[Iron plate]]s, and [[Water]]. Can be used to create various items.
| 3 || 2250
|-
|-
| {{imagelink|lubricant|Lubricant}} || Converted from [[Heavy oil]]. Used mainly to create [[Express transport belt]]s  and [[Engine]]s.
| 4 || 1909
|-
|-
|}
| 5 || 1714
 
|-
== Machines ==
| 6 || 1588
 
|-
{| class="wikitable"
| 7 || 1500
 
|-
| {{Imagelink|Oil refinery|Oil refinery}} || Converts [[Crude oil]] into [[Heavy oil]], [[Light oil]], and [[Petroleum gas]].
| 8 || 1434
|-
| 9 || 1384
|-
| 10 || 1344
|-
| 11 || 1312
|-
| 12 || 1285
|-
| 17 || 1200
|-
| 20 || 1169
|-
| 30 || 1112
|-
| 50 || 1067
|-
| 100 || 1033
|-
| 150 || 1022
|-
| 200 || 1004
|-
| 201 || 999
|-
|-
| {{Imagelink|Chemical plant|Chemical plant}} || Changes liquid to other forms as well as crafting some recipes that require liquids.
| 261 || 799
|-
|-
| {{imagelink|pumpjack|Pumpjack}} || Extracts [[Crude oil]] from Oil fields.
| 300 || 707
|-
|-
| {{imagelink|boiler|Boiler}} || Creates 165°C steam when [[fuel|fueled]].
| 400 || 546
|-
|-
| {{imagelink|heat exchanger|Heat exchanger}} || Creates 500°C steam when heated using a [[nuclear reactor]].
| 500 || 445
|-
|-
| {{Imagelink|Steam engine|Steam engine}} || Uses steam to generate [[Electric system|electricity]].
| 600 || 375
|-
|-
| {{imagelink|steam turbine|Steam turbine}} || Uses steam to generate [[Electric system|electricity]].
| 800 || 286
|-
|-
| {{Icon|Assembling machine 2||Assembling machine 2}} or {{Icon|Assembling machine 3||Assembling machine 3}} || Puts liquids into or out of [[barrel]]s.
| 1000 || 230
|-
|-
|}
|}
Note that all fluid throughput numbers listed above are not directly calculated by the game, but are a result of the underlying fluid mechanics.


== Piping ==
Approximate formula for throughput by number of pipes between two pumps:
<!--''This section should explain: link to liquid stacks, pipe window and how to get information out of it (animations would be handy), pipes and their max. throughput, link to maximum length of pipes, difference between pipe and pipe to ground, storage tank and its special connections and comparing to pipes (is nothing than a big pipe), pump and max. throughput (how much needed), how to make short connections, long distance piping, refreshing the pressure for more throughput, how to pump equal amounts of liquids in two directions...'' -->
<pre>1 <= pipes < 197:
    flow = 10000 / (3 * pipes - 1) + 1000
pipes >= 197:
    flow = 240000 / (pipes + 39)</pre>


''Piping'' is the most common way to move liquids in factorio.
The above formula is empirically inferred from the actual measurements, and is not an accurate representation of what happens in the game code. Starting with pipe lengths above 166, its result may be 1 too high compared to in-game measurements with pumps.[https://forums.factorio.com/viewtopic.php?p=572234#p572234]


Key entities used in piping and general fluid handling:
=== Barrels ===
'''[[Barrel]]s''' are used by [[Assembling machine]]s to effectively "bottle" fluids into an item that can be handled like any other item; carried in an inventory, placed in chests and handled by [[Inserters]]. This allows the player to transport fluids via the [[belt transport system]] and the [[logistic network]]. Assembling machines are also used to empty the barrels, depositing their contents to pipes and leaving an empty barrel for another use.


{| class="wikitable"
=== Railway ===


| {{imagelink|pipe|Pipe}} || Used to direct the flow of liquids.
'''[[Railway]]''' is another method of transporting fluids, and can be conducted in two ways: Either the fluids are directly pumped into a [[fluid wagon]], or they are poured into barrels and loaded into [[cargo wagon]]s. Both methods have their advantages:
|-
| {{Imagelink|Pipe to ground|Pipe to ground}} || Used to cross other pipes or belts.
|-
| {{Imagelink|Storage tank|Storage tank}} || Stores liquids for later use.
|-
| {{Imagelink|Offshore pump|Offshore pump}} || Provides [[Water]] extracted from a water tile.
|-
| {{imagelink|pump|Pump}} || Moves fluids in the direction of the arrow. Prevents fluid from moving in the opposite deirection.
|-
|}


==History==
'''Advantages of using fluid wagons'''
* Faster loading and unloading
* Higher capacity (25k vs 20k)


Water was the first fluid to be added to the game. In [[Version history/0.9.0|version 0.9]] the [[oil processing]] system, and therefore new fluids, including crude oil and petroleum gas, were added.
'''Advantages of using barrels in cargo wagons'''
* A single cargo wagon can transport multiple types of barrelled fluid (and regular items at the same time)
* Cargo wagons, [[Fluid wagon#Troubleshooting|as opposed to fluid wagons]], don't need to be perfectly aligned to be (un-)loaded, allowing for more flexible train station designs


==See also==
==See also==
Line 104: Line 150:
* [[Oil processing]]
* [[Oil processing]]
* [[Power production]]
* [[Power production]]
* [http://factorioforums.com/forum/viewtopic.php?f=18&t=19851 Indepth post about fluid mechanics]
* [https://forums.factorio.com/viewtopic.php?f=18&t=19851 In-depth post about fluid mechanics]
* [https://forums.factorio.com/viewtopic.php?f=5&t=46030 How many pumps after how many pipes for how much throughput]
* [https://www.reddit.com/r/factorio/comments/6w9kwi/factorio_and_fluid_mechanics_science_facts_myths/ Another in-depth examination of fluid mechanics]

Latest revision as of 17:15, 18 August 2022

Fluids are non-solid items, such as water and oil. They can normally only exist inside entities for fluid handling (like pipes), and buildings that have fluids as input ingredients or products (like an oil refinery).

Fluids

"Fluids" tab on the production statistics screen.

The following fluids are available in-game:

Water.png
Water
Crude oil.png
Crude oil
Petroleum gas.png
Petroleum gas
Light oil.png
Light oil
Heavy oil.png
Heavy oil
Lubricant.png
Lubricant
Sulfuric acid.png
Sulfuric acid
Steam.png
Steam

Mechanics

Fluids cannot be carried by the player, moved using inserters, dropped on the ground, nor stored in chests, unless the fluids are stored in barrels. They cannot be spilled or even dumped in a lake, and are counted in continuous fractions, rather than discrete integers.
When the player picks up a structure that contains fluids, the contained fluid will try to flow into connected structures and any excess fluid that does not fit is destroyed.

Storage

In the game, fluid is held in entities that behave as vessels (fluid boxes) of a defined size (volume). The vessels automatically connect to each other if their inputs/outputs are adjacent (pipes connect to all directions) and allow fluids to flow between them.

The volume of fluid contained in a fluid box is a value between 0 and the maximum volume. For instance, the pipe can hold 100 units of fluid, therefore the value in the pipe can be a number between 0 and 100. The level of fluid in a given entity is manifested by a percentage of the entity's maximum volume that is being occupied by a fluid. It can be observed in pipes and tanks; they have windows through which the fluid is seen at a certain level, or perhaps even as just a small trickle.

Fluid mixing

GUI of a pipe inside a fluid system containing mixed fluids. Clicking the trash can icon next to a fluid will flush that fluid from the system.

The game will prevent players from accidentally mixing fluids when placing most buildings, e.g. pipes containing different fluids cannot be placed directly next to each other. However, not every possible case of fluid mixing is considered, so the player may still mix fluids accidentally or by purposely working around the building restrictions. A fluid system containing mixed fluids can be cleared of the undesired fluids in the GUI of a pipe or storage tank that is part of that fluid system. Fluids that are flushed from pipes or storage tanks are deleted permanently.

In a fluid system that contains mixed fluids, the alt-mode fluids icons on its pipes/storage tanks will reflect the fluid that is contained in that specific structure. So, it may look like a fluid system only contains one fluid when looking at the alt-mode icons, when in reality it contains multiple fluids which are located in some other connected structures. The GUI of a connected pipe or storage tank will always show all fluids contained in the fluid system.
This means that if the game disallows connecting two pipes that look like they contain the same fluid with "Cannot connect systems with different fluids", one of the fluid systems contains multiple fluids. This can solved easily by opening the GUIs of the pipes that the game refuses to connect which will show the extra fluid and allow flushing it from the fluid system.

Flow

All connected tanks and pipes are treated as a single vessel in that the level of fluid must be equal in all parts, to even out pressure exacted by a higher fluid level on smaller ones. This is why level is also often referred to as pressure, even though pressure is actually caused by a difference in level between two entities. All flow of fluid that happens between pipes is to achieve this balance (pumps practically ignore it and buildings disrupt it; more on that further below). The flow rate between pipes is dependent on pressure (the difference in level between the adjacent entities), it becomes slower as pipes even their levels out.

Coming back to how the 'level' is defined, this also means that all connected pipes and tanks attempt to even out to the same percentage of their respective volumes. For example, if 12,550 units of fluid are left to flow into a storage tank of 25,000-unit capacity with one pipe of 100-unit capacity connected, there will be 12,500 units in the storage tank and 50 units in the pipe, both being filled to the same percentage (50%) of their capacities, even though the amounts themselves are unequal.

Machines that produce fluids put them in their output slots, which are related to a specifically labeled output pipe socket somewhere on the machine (pressing Alt reveals the labels). The slot will attempt to empty itself into the entity connected to the machine's socket, unless it is full, or contains a non-matching fluid. Machines that consume fluids also have an accordingly labeled pipe input socket. If an entity containing the correct fluid is connected to it, the machine will start behaving like a pipe that can never be filled, meaning the fluid from connected pipes and tanks drains into the machine at a fixed rate, until the machine's input slot is full. There may be machines that have pipe sockets for both input and output (like a drill placed over uranium ore). They then drain the fluid for themselves first, and once full, behave as a regular pipe that attempts to even out its level with adjacent entitites. If there are multiple output/input sockets for one fluid on a machine, their activity is distributed to them equally unless some of them are blocked/full.

Temperature

Temperature is currently only relevant in heating water as a medium for power generation. Even though all fluids in the game have a temperature value, it is generally the default 15°C.

Energy, whether harnessed from fuel in boilers, or from nuclear power through heat exchangers, can be used to turn water to steam, being a liquid form of work. Steam holds energy at a ratio of 0.2 kJ per °C per unit. In other words: 0.2 kJ of work is necessary to heat a unit of steam by one °C. Since steam/water is set to have a maximum temperature of 1000°C and minimum of 15°C, the most work that can be done on one unit is 197 kJ.

In practice, this is barely utilized in a great variety: Boilers only output steam of 165°C temperature, and heat exchangers only output 500°C hot steam, never hotter, never colder; if insufficient energy is supplied, the heaters do not output steam altogether. The steam also does not grow colder over time. Using the 165°C steam in a steam engine has the same effect as using it in a steam turbine, although it is impractical, since turbines are made to consume 500°C (superheated) steam, generating proportionally more power. All of this makes for no need of exact calculations.

Transport

Fluids can be transported through pipelines, barrels, or railway. It is generally practical to use piping for short-distance distribution to machines (or barrelling, if there is need to use belts), and railway transportation for longer distances.

Pipelines

Eight pipelines, each carrying a different fluid.

Pipes are the most basic way to channel fluids from A to B. They automatically connect to any adjacent pipe and can do so to all four cardinal directions simultaneously. Underground pipes only work in two opposite directions, linking to another underground pipe on one side, and to another entity on the other. If a pipe section becomes too long without using pumps, all fluid inside it will be "spread thin", resulting in very slow flow and preventing machines to use its contents effectively. Tanks behave the same as pipes, except their volume is much greater, which can cause this inconvenience over a much smaller distance if multiple tanks are used. Underground pipes can help alleviate this issue; although they can connect a distance of up to 10 tiles, their volume is always equivalent to two pipes.

Pumps use electrical power to transfer fluids in one direction very quickly. They also block any back-flow, which means they can pressurize a section of piping, filling it as much as possible. This is very useful to counteract the "thin spread" outlined above, among other things. They can also be disabled using the circuit network which stops fluid flow through the pump.

The table below shows how fast will fluid flow in a pipeline with a certain frequency of pumps. If a higher flow rate is desired, pumps should be placed more frequently. Because underground pipes only count as 2 regular pipes in terms of volume, a full-length section only counts as two pipes in this table, if a pump is placed between each underground section. Placing a filled storage tank before a pump ensures maximum possible flow rate and is therefore a suitable start of any pipeline.

Number of pipes
between two pumps
Maximum flow 
(u/sec)
0 (pump to pump) 12000
0 (tank to pump) 12000
0 (pump to tank) 12000
0 (pump to boiler to pump) 12000
0 (pump to 2 boilers to pump) 6000
1 6000
2 3000
3 2250
4 1909
5 1714
6 1588
7 1500
8 1434
9 1384
10 1344
11 1312
12 1285
17 1200
20 1169
30 1112
50 1067
100 1033
150 1022
200 1004
201 999
261 799
300 707
400 546
500 445
600 375
800 286
1000 230

Note that all fluid throughput numbers listed above are not directly calculated by the game, but are a result of the underlying fluid mechanics.

Approximate formula for throughput by number of pipes between two pumps:

1 <= pipes < 197:
    flow = 10000 / (3 * pipes - 1) + 1000
pipes >= 197:
    flow = 240000 / (pipes + 39)

The above formula is empirically inferred from the actual measurements, and is not an accurate representation of what happens in the game code. Starting with pipe lengths above 166, its result may be 1 too high compared to in-game measurements with pumps.[1]

Barrels

Barrels are used by Assembling machines to effectively "bottle" fluids into an item that can be handled like any other item; carried in an inventory, placed in chests and handled by Inserters. This allows the player to transport fluids via the belt transport system and the logistic network. Assembling machines are also used to empty the barrels, depositing their contents to pipes and leaving an empty barrel for another use.

Railway

Railway is another method of transporting fluids, and can be conducted in two ways: Either the fluids are directly pumped into a fluid wagon, or they are poured into barrels and loaded into cargo wagons. Both methods have their advantages:

Advantages of using fluid wagons

  • Faster loading and unloading
  • Higher capacity (25k vs 20k)

Advantages of using barrels in cargo wagons

  • A single cargo wagon can transport multiple types of barrelled fluid (and regular items at the same time)
  • Cargo wagons, as opposed to fluid wagons, don't need to be perfectly aligned to be (un-)loaded, allowing for more flexible train station designs

See also