Types/FluidBox: Difference between revisions
Deadlock989 (talk | contribs) |
(copied max temp description to min temp, words) |
||
Line 34: | Line 34: | ||
'''Type''': [[Types/string]] | '''Type''': [[Types/string]] | ||
Can be used to specify which fluid is allowed to enter this fluid box. [https://forums.factorio.com/viewtopic.php?f=28&t=46302] | Name of a [[Prototype/Fluid]]. Can be used to specify which fluid is allowed to enter this fluid box. [https://forums.factorio.com/viewtopic.php?f=28&t=46302] | ||
=== render_layer === | === render_layer === | ||
Line 52: | Line 52: | ||
'''Type''': [[Types/double]] | '''Type''': [[Types/double]] | ||
The minimum temperature allowed into the fluidbox. | The minimum temperature allowed into the fluidbox. Only applied if a <code>filter</code> is specified [https://forums.factorio.com/viewtopic.php?p=496738#p496738]. | ||
<syntaxhighlight lang="lua">minimum_temperature = 100.0</syntaxhighlight> | <syntaxhighlight lang="lua">minimum_temperature = 100.0</syntaxhighlight> | ||
Line 59: | Line 59: | ||
'''Type''': [[Types/double]] | '''Type''': [[Types/double]] | ||
The maximum temperature allowed into the fluidbox. Only | The maximum temperature allowed into the fluidbox. Only applied if a <code>filter</code> is specified [https://forums.factorio.com/viewtopic.php?p=496738#p496738]. | ||
<syntaxhighlight lang="lua">maximum_temperature = 1000.0</syntaxhighlight> | <syntaxhighlight lang="lua">maximum_temperature = 1000.0</syntaxhighlight> |
Revision as of 11:40, 8 October 2020
Basics
Used to set the fluid amount an entity can hold, as well as the connection points for pipes leading into and out of the entity.
Mandatory properties
pipe_connections
Type: Types/table of Types/PipeConnectionDefinition
Max number of members is 255.
Optional properties
base_area
Type: Types/double
Default: 1
Must be greater than 0.
base_level
Type: Types/double
Default: 0
height
Type: Types/double
Default: 1
Must be greater than 0.
filter
Type: Types/string
Name of a Prototype/Fluid. Can be used to specify which fluid is allowed to enter this fluid box. [1]
render_layer
Type: Types/RenderLayer
Default: "object"
pipe_covers
Type: Types/Sprite4Way
The pictures to show when another fluid box connects to this one.
pipe_picture
Type: Types/Sprite4Way
minimum_temperature
Type: Types/double
The minimum temperature allowed into the fluidbox. Only applied if a filter
is specified [2].
minimum_temperature = 100.0
maximum_temperature
Type: Types/double
The maximum temperature allowed into the fluidbox. Only applied if a filter
is specified [3].
maximum_temperature = 1000.0
production_type
Type: Types/string
Default: "None"
Possible values:
- "None"
- "input"
- "input-output"
- "output"
secondary_draw_order
Type: Types/int8
Default: 1
Set the secondary draw order for all orientations.
secondary_draw_orders
Type: Types/table of Types/int8
Default: {north = 1, east = 1, south = 1, west = 1}
Set the secondary draw order for each orientation.
Example
fluid_box =
{
base_area = 1,
height = 2,
base_level = -1,
pipe_covers = pipecoverspictures(),
pipe_connections =
{
{type = "input-output", position = {-2, 0.5}},
{type = "input-output", position = {2, 0.5}}
},
production_type = "input-output"
},